Window

The window for bridge at MP 59 will Start at 0300 Sunday morning for 36 hrs.

Howard Allington

BLET LC 758
Vancouver,WA
———————————

36 HOUR FALLBRIDGE BRIDGE MOW WINDOW

THERE IS A 36 HOUR PLANNED MAINTENANCE WINDOW ON THE FALLBRIDGE SUBDIVISION BEGINNING AT 0200-04 TO 1600-05. THE PRIMARY FOCUS IS
REPLACING THE WIND RIVER BRIDGE AT MP 58.8. DURING THIS WINDOW WE
HAVE NUMEROUS ASSOCIATED WORK GROUPS WORKING ACROSS THE SUBDIVISION.
WE WILL HAVE LIMITED OPPORTUNITIES TO RUN TRAFFIC DURING THIS WINDOW,
HOWEVER WE STILL PLAN ON ADVANCING AND OPERATING TRAINS AS
OPPORTUNITIES BECOME AVAILABLE. ADDITIONALLY, WE ARE PLANNING 2
DETOURS PER DAY BETWEEN VANCOUVER AND KLAMATH FALLS AS WELL AS 2
DETOURS BETWEEN VILLARD JUNCTION AND PORTLAND ON THE UP RR.
WE HAVE ADDITIONAL HALLCON VANS AND DRIVERS, MECHANICAL RESPONDERS,
AND OFFICERS PRE-POSITIONED DURING THIS WINDOW TO SAFELY EXECUTE OUR
OPERATING PLAN FOR SHUT DOWN AND START UP.
THANK YOU FOR YOUR TIME WHILE WE HARDEN THE RAILROAD AND MAKE A SAFER,
MORE RELIABLE INFRASTRUCTURE FOR OUR EMPLOYEES AND CUSTOMERS.
BELOW IS A LIST OF PLANNED ACCOMPLISHMENTS DURING THIS OUTAGE:

” REPLACE BRIDGE 58.8
” REPLACE 2 #20 TURNOUTS
” REPLACE 1 #11 TURNOUT
” ELIMINATE 55 JOINTS
O WILL WELD @ 30 OTHER JOINTS CREATED DURING THE WINDOW
” INSTALL 4 NEW FROGS
” INSTALL 826 CONCRETE TIES
” SURFACE 6+ MILES OF TRACK AND TURNOUTS
” DITCHING 40 SPANS OF SLIDE FENCE (@ 55,000′)
” SETTING AND CONCRETING 40 FOOT PILING FOR THINK TANK “BELLY FENCE”.
O REMOVING 4 SPANS OF 32 WIRES FOR INSTALL
” REPLACING/UPDATING 50 SPANS WORTH OF HOG FENCE AND PULL PLUGS
” WISHRAM M2 EXTENSION PHASE 2 CUTOVER
” CUT IN 7 SETS OF IJ’S FOR PHASE 3 OF WISHRAM M2 EXTENSION.”

Hit Team

System testing team will be on the Northwest Division next week. Uncertain which sub division they will key in on.


— 
Kevin Howard
BLET Safety Coordinator
NW Division of BNSF

Howard Allington

BLET LC 758
Vancouver,WA

This message is covered by the Electronic Communications Privacy Act, 18 U.S.C. §§ 2510-2521, and is legally privileged. This email and any files transmitted with it are confidential and are intended solely for the use of the individual or entity to whom it is addressed. If you are not the intended recipient or the person responsible for delivering the email to the intended recipient, please be advised that you have received this email in error and that any use, dissemination, forwarding, printing, or copying of this email and any file attachments is strictly prohibited. If you have received this email in error, please immediately notify us by reply email to the sender. Please delete this email and its attachments from your system and do not retain any copies.